MCQ
2361. For ground fault we prefer-
Plain impedance relay
Directional over current relay
Mho relay
Reactance relay
2362. Outdoor sub-station requires-space.
Less
More
Medium
Any of the above
2363. Factors on which soil resistance depends/RPCI--
depth of the electrode
moisture
Nacl
all the above
2364. The voltage of a particular bus is regulated by controlling the --
Active power of the bus
Reactive power of the bus
Phase angle
Phase angle and reactive power
2365. The relay used for feeder protection --
Under voltage relay
Translay relay
Thermal relay
Buchholz relay
2366. Admittance relay-
Non-directional relay
Directional relay
Differential relay
None of the above
2367. Which of the following equipment is used to limit short circuit current level in a sub-station?
Isolator
Lightning switch
Coupling capacitor
Series reactor
2368. The relay used for phase fault protection of short transmission lines is-
Reactance relay
Mho relay
Impedance relay
IDMT relay
2369. Surge absorbers are used for protection against-
High-voltage low-frequency oscillations
High-voltage high-frequency oscillations
Low-voltage high-frequency oscillations
Low-voltage low-frequency oscillations
2370. The bus-bar zone, the purpose of protection includes-and-
Bus-bars, isolating switches, circuit breakers
Transformers, relays, circuit breakers
Transformers, conductors and relays
None of the above
2371. The main function of a fuse is to-
Protect the line
Open the circuit
Prevent excessive currents
None of the above
2372. The under voltage relay can be used for--
Generators
Bus bars
Transformers
All of the above
2373. The relay with inverse time characteristic will operate within--
1.5 sec
5 to 20 sec
5 to 10 sec
20 to 30 sec
2374. For the protection of lines against faults Involving variable fault resistance, the preferred relaying scheme is a-
Plain impedance relay
Directional over-current relay
Mho relay
Reactance relay
2375. An ideal location for the substation would be at ---the of load.
Centre of gravity
Load centre
Nearer to consumer
None of the above
2376. The over-voltage surge in power systems may be caused by-
Lightning
Resonance
Switching
All of the above
2377. The single phasing relays are used for the protection of-
Single phase motors only
Two phase motors only
Two single phase motors running in parallel
Three phase motors
2378. Where severe synchronising swing occur, the relay employed is
Impedance relay
Mho relay
Reactance relay
Induction relay
2379. Average resistance of human body is-
500 ohms
1000 ohms
1500 ohms
2000 ohms
2380. In the case of transmission line protection, over current relay is used-
Only up to 110kV
Only up to 220kV
Only up to 50k V
Only up to 1100k V