MCQ
5501. Which of the following bus-bar schemes has the lowest cost?
Ring bus-bar scheme
Single bus-bar scheme
Breaker and a half scheme
Main and transfer scheme
5502. DC shunt relays are made of--
Few turns of thin wire
Few turns of thick wire
Many turns of thin wire
Many turns of thick wire
5503. Which of the following can be used for bus-bars?
Tubes
Bars
Rods
Any of the above
5504. The relay with inverse time characteristic will operate within--
1.5 sec
5 to 20 sec
5 to 10 sec
20 to 30 sec
5505. A bus-bar is rated by-
Current only
Voltage only
Current, voltage and frequency
Current, voltage, frequency and short circuit current
5506. Which is the main relay for protecting up to 90% of the transmission line-length in the forward direction?
Directional over-current relay
Mho relay
Carrier current protective relay
Impedance relay
5507. Zero sequence current is used for relaying purpose only in the case of--
Phase over-current relay
Phase impedance relay
Ground over-current relay
Ground impedance relay
5508. The under voltage relay can be used for--
Generators
Bus bars
Transformers
All of the above
5509. For arc welding-
alternating current with high frequency is used
direct current is used
alternating current with low frequency is used
any one of these
5510. The material used for bus-bar should have-
Low resistivity
Low cost
High-softening temperature
All of the above
5511. In the case of transmission line protection, over current relay is used-
Only up to 110kV
Only up to 220kV
Only up to 50k V
Only up to 1100k V
5512. Which one of the following relay has the capability of anticipating the possible major fault in a transformer?
Over current relay
Differential relay
Buchholz relay
Over-fluxing relay
5513. -relays are used for phase faults on long line.
Impedance
Reactance
Mho
Either of the above
5514. The relay operating speed depends upon-
The spring tension
The rate of flux built up
Armature core air gap
All of the above
5515. How many relays are used to detect inter phase fault of a three-line system?
One
Two
Three
Six
5516. Both voltage and current signals are required for-
A plain over-current relay
A differential relay
A directional relay
A biased directional relay
5517. When an alternator connected to the bus-bar is shut down the bus-bar voltage will --
Fall
Rise
Remain unchanged
None of the above
5518. Relays can be designed to respond to changes in-
Resistance, reactance or impedance
Voltage and current
Light intersity
All of the above
5519. The single phasing relays are used for the protection of-
Single phase motors only
Two phase motors only
Two single phase motors running in parallel
Three phase motors
5520. -relays are preferred for phase fault on short transmission line
Induction type
Reactance
Impedance
None of the above